Key Specifications
|
Specification
|
Detail
|
|---|---|
|
Brand
|
ABB
|
|
Model / Order Code
|
REM545AG228AAAA
|
|
Series
|
Relion REM 545 Machine Protection Terminal
|
|
Application
|
Generators, gen-transformer units, MV sync/async motors
|
|
CT / VT Inputs
|
3-phase I (1 A / 5 A), 3-phase V (line-line / line-neutral), residual I
|
|
Binary Inputs
|
25 (config-dependent)
|
|
Relay Outputs
|
18
|
|
RTD / Analog
|
Optional RTD inputs for stator/bearing/ambient temp
|
|
Protection Core
|
Overcurrent, earth fault, diff (opt), thermal, negative-seq, U/F, U/V, excitation, impedance, reverse power
|
|
Motor Extras
|
Stall, locked-rotor, start-count, start supervision
|
|
Generator Extras
|
Loss-of-excitation, under-impedance, reverse/low power, gen-motoring
|
|
Control
|
Breaker control, sync-check, local/remote, PLC logic
|
|
Measurement
|
I, V, P, Q, PF, f, energy, harmonics/disturbance records
|
|
Communication
|
SPA, LON, Modbus (RTU); IEC 61850 via SPA-ZC 400 adapter; optical serial link
|
|
HMI
|
Graphic LCD, detachable for door mounting
|
|
Aux Supply
|
Wide-range DC (order-code dependent, commonly 48–250 VDC or 110/220 VDC)
|
Product Overview
The REM545AG228AAAA sits in the MV switchgear panel as a single box replacing discrete overcurrent, earth-fault, thermal, voltage, frequency and logic relays. On the generator side it is used as primary protection for diesel/hydro/steam plant gen-sets and gen-transformer blocks. On the motor side it protects critical MV loads where start-up stress and thermal memory matter.
Signal acquisition is via conventional CT/VT or low-power sensors; the terminal samples continuously for oscillography, event logging and sequence-of-events reporting. The detachable graphic HMI allows panel-door mounting while the main body stays on the rack.
Core Functions
- Rotating-machine differential / restricted earth fault (option)
- Thermal overload with RTD backup and cooling-model memory
- Negative-sequence / unbalanced load protection
- Voltage & frequency windows (27/59, 81, 59/27)
- Excitation supervision (loss-of-field, over/under-excitation)
- Under-impedance as generator backup
- Reverse / low forward power for gen motoring
- Stall, locked-rotor, cumulative starts for motors
- PLC logic for permissives, interlocks, load-shedding
- Disturbance recording + 1000-event log + self-diagnostics
Typical Applications
- Small/medium diesel, hydro, steam power plants
- Industrial captive power & generator-transformer bays
- Offshore / marine generator protection (certified)
- MV pumps, mills, crushers, fans, compressors
- Retrofit of legacy electromechanical machine panels
- Substation automation via SPA-ZC 400 → IEC 61850 station bus